High security cell windows must provide natural light while meeting the demanding security requirements of custody and detention environments. For architects, contractors and facilities teams, selecting a suitable window means considering the complete assembly, the existing opening and the project’s approved security specification.

We manufacture glass and ferro-concrete security cell windows and rooflights used in police stations, prisons and courts. Our cell unit security panels include standard formats for custody suites and options made to fit existing structures.

What matters when specifying high security cell windows?

A window for a secure facility should be considered as part of the surrounding wall, rather than as glazing alone. The required level of resistance, fixing method, geometry and safety details depend on the room’s purpose and the project’s security brief.

  • Resistance to damage and forced entry. Establish the relevant performance requirements for the whole window assembly, including frame, glazing and fixings.

  • Safe internal detailing. Review accessible edges, projections and potential ligature attachment points in consultation with the custodial design team.

  • Daylight and visibility. Balance security with the natural light and privacy needed for the particular room.

  • Ventilation. Where an opening incorporates ventilation, specify its function and security requirements separately from the glazed panel.

  • Inspection and maintenance. Consider whether staff can inspect the assembly safely and access replacement parts without compromising security.

The chosen design should respond to the building’s actual risks. A police custody suite, for example, may have different requirements from a high-security rooflight or a replacement window in an older prison building.

Key features of high security cell windows

Security cell windows are specifically designed for controlled environments, where the whole opening forms part of the building’s protective construction. Unlike ordinary windows, the choice of glazing, concrete surround and fixing hardware must be evaluated against the intended security performance.

For a prison or police station, key features worth examining include the strength and integrity of the combined assembly, resistance to forced entry or removal, safe detailing at accessible surfaces, and the durability of components exposed to daily use. Daylight, visibility and cleaning access matter too. A window may be installed within a cell wall, custody corridor or another secure area, but the same design is not necessarily appropriate everywhere.

Precast ferro-concrete security panels can provide an integrated surround for specialist glazing. The arrangement must be compatible with the supporting structure and the fixing method. What matters is the tested or otherwise substantiated performance of the particular assembly, not an unverified claim that every prison window is indestructible.

Security requirements, design guidance and testing

For police custody projects, the project team should establish the applicable Police Building Design Guide requirements and confirm what evidence of performance is needed. Our custody suite cell windows have been developed to satisfy the relevant Home Office design requirements, including static load testing up to 165 kN/m², as stated in our published product information. That figure describes a particular stated performance characteristic; it must not be treated as a universal requirement for every cell window or evidence of resistance to every possible type of attack.

Ask for the relevant product drawings, test information and fixing specification for the configuration being proposed. A test value quoted for one component or assembly does not automatically establish the performance of a modified installation. Security glazing and supporting construction need to be assessed together, particularly where the surrounding wall or fixing detail differs from a tested arrangement.

Standards for burglary-resistant or ballistic products may be discussed in other security contexts, but they should not be presented as certification held by our cell windows unless the particular product documentation confirms it.

For a custody project, the responsible design team should set out the relevant threat scenarios and performance criteria. These may include attempts to force an opening, strike the glazed surface or interfere with accessible fixings. The window’s frame, security glazing, reinforcement, bolts and surrounding wall must be considered together. A published static load result is useful evidence for a stated test condition, not a guarantee against every form of physical attack.

Where documentation is required for approval or project handover, request evidence specific to the proposed product and configuration. This helps the architect distinguish tested characteristics from design assumptions, and identify whether a bespoke detail requires further assessment. Compliance must be judged against the actual project brief and applicable guidance rather than asserted on the basis of a product description alone.

Custody suite cell windows for police stations

Our published range includes four recommended standard-format cell windows, in landscape and portrait configurations. The most commonly specified landscape format is 1891 mm wide by 1120 mm high. These dimensions are useful starting points for the design team, but do not replace a site-specific dimensional check.

We manufacture precast glass and ferro-concrete custody suite cell windows. Published options include grey concrete as standard, alternative concrete colours, sandblasted lenses for increased obscurity, and stainless steel or welded reinforcement options. Standard fixing details include Hilti-type sleeve-anchor through-bolts to the jambs. The appropriate configuration and fixing detail must be checked for the intended installation.

The choice of a landscape or portrait window affects the dimensions of the opening and the relationship between glazing, surrounding concrete and wall construction. Each configuration should be checked against the planned security arrangements, ventilation requirements and maintenance access. Our range provides options for UK custody projects, but a comprehensive project specification still needs drawings and technical confirmation.

A new-build opening may be designed around a standard format, whereas refurbishment often requires a different approach. Before selecting a panel, review the wall construction, clear opening, reveals and fixing positions, along with access for delivery and installation.

Custody suite cell windows for police stations

Replacing windows in existing secure buildings

Some existing police stations cannot accommodate the standard custody-suite design because their apertures and surrounding structures differ. We can manufacture replacement cell windows to suit individual project requirements, including arrangements with:

  • Arched-profile heads

  • Monolithic cills and jambs

  • Projecting reinforcement bars

  • Threaded sockets for cleat fixing to existing reveals

These options make it possible to consider a replacement within an existing opening, subject to technical assessment. Existing structures often have constraints that are not obvious from the opening measurements alone. The responsible project team should confirm the condition and load path of the substrate, whether the proposed fixing hardware can be installed without damaging adjacent finishes, and whether the finished assembly remains compatible with the security brief.

When replacing prison cell windows, the goal is not merely to fit new glazing into an old frame. A refurbishment specification should address the integrity of the full opening and how the selected construction links to the wall. Different fixing details or an altered reinforcement arrangement can affect the strength of the assembly, so published test evidence should be checked for relevance to the replacement design. They should not be described as automatically equivalent to a standard tested assembly. Our technical department can advise on feasible configurations when supplied with drawings and the relevant project requirements.

High-security glazing, fixings and practical details

The design team should establish the required glazing performance and how the pane will be retained within the surrounding construction. High security glazing may involve laminated materials, but a particular make-up should not be assumed without a verified specification.

Fixings are equally important. Check the substrate, anchor positions, edge distances and interfaces with adjacent materials. Potentially accessible fittings and junctions should be reviewed against the relevant custody safety requirements. Surface finish, obscurity and cleaning arrangements may also influence which configuration is appropriate.

Glazing selection is more than a choice between transparent and obscured panes. Our product information describes specialised laminate constructions that can combine glass and polycarbonate or acrylic layers to withstand demanding conditions. However, the proposed build-up and its performance need to be confirmed for the particular security cell window. Even when high security glazing is used, its retention within the frame remains critical.

Accessible fittings should be reviewed with the relevant custody specialists to address tampering, potential ligature points and any risk posed by broken materials. Hardware and bolts may be concealed or otherwise protected where the approved design calls for it, but those measures cannot be assumed for every product.

If ventilation, privacy treatments or internal grilles are needed, these should be detailed explicitly in the project specification. They are not standard features of every window in our range.

Security rooflights and related applications

Our cell window constructions are also used as high-security rooflights above custody and cell areas. The published rooflight references include CU/R165/75 and CU/R200/75. Other products in our range may be suitable in some security applications, depending on the technical brief. For advice on selection, see our cell unit security panel range.

Rooflight specifications also need to address structural support, access, weatherproofing and the location of any exposed internal surface. These considerations should be resolved with the wider design team before manufacture.

Information to provide when requesting a cell window specification

To help us assess the appropriate format, provide the building type, intended use, applicable security requirements, opening dimensions, wall build-up and available fixing locations. It is also helpful to explain whether the project is a new police custody facility, a prison refurbishment or a secure rooflight installation. This gives our technical department the context needed to discuss the range rather than recommend a standard panel without checking its application. Drawings or photographs of existing reveals are particularly helpful for refurbishment.

We can discuss standard and bespoke precast configurations with the project’s architect or contractor. Final suitability must be confirmed against the project-specific requirements and supporting product information.

Frequently asked questions

What type of window is suitable for a police custody cell?

A custody cell window should be selected against the project’s approved security and safety requirements, rather than the appearance of the glazing alone. We manufacture precast cell windows for police stations and related secure facilities. A specification should check the entire assembly, its strength and fixing method, and the relevant Home Office design guidance. We can discuss standard formats and bespoke options when the opening and performance requirements are known.

Yes. Where an older prison or police building cannot accommodate a standard window, we can consider bespoke arrangements with alternative heads, cills, jambs or fixing details. The dimensions, condition of existing structures and available anchor positions need to be checked. A replacement with different hardware or reinforcement should not be treated as identical to a previously tested configuration without supporting evidence.

No. Our published custody-suite information refers to static load testing up to 165 kN/m², but this should not be applied to every prison window or bespoke opening. The responsible designer needs to check the stated test conditions, product construction and any variations. Resistance to forced entry, tampering and other security risks should be assessed against the complete specification, not inferred from a single load figure.

They serve related security purposes, and we manufacture high-security rooflights based on our cell window constructions. However, their installed position changes the structural and practical requirements. A rooflight specification should consider support, weatherproofing, accessibility and the security of the underside. The appropriate glazing, frame and fixing arrangement should be confirmed for each project.

Provide the building use, security brief, opening dimensions, wall construction, drawings or photographs, intended fixing locations and any refurbishment constraints. For custody cell windows, identify relevant performance and safety requirements and whether daylight, privacy or secure ventilation needs to be considered. Our technical department can use that information to discuss appropriate options and documentation, while the project team remains responsible for confirming suitability.